HVAC Definitions
In this blog, we will discuss commonly used HVAC terms in the building services industry.
Learning or revising definitions before working with them is always recommended.
- Understanding the Terminology: HVAC design involves using many technical terms that may be unfamiliar to beginners in the field.
- Building a Foundation of Knowledge: Building a strong foundation helps you understand how all HVAC components and systems work together.
- Communicating Effectively: Learning HVAC definitions improves communication with others in the field and helps avoid misunderstandings.
- Saving Time and Effort: Learning HVAC definitions saves time and effort by reducing the need for repeated research and clarification, which can slow down the learning process.
Here are the frequently used terms in the HVAC industry.
Air Balancing
This is the process of adjusting airflow in a building to ensure that each area receives the required amount of air.
Air Contaminants
Unwanted airborne constituents that might reduce the acceptability or adequacy of air quality.
Air Filtration
This is the process of removing particles and pollutants from the air in a building to improve indoor air quality.
Air Handling Unit (AHU)
This is a device that moves air through a building. It takes in air from outside, filters it, and then circulates it through the building.
Diversity Factor
Relates to the thermal characteristics of the building envelope, temperature variations, and occupancy load.
Ductwork
Airtight passages that carry conditioned air throughout a building.
Air Leakage
Air that escapes from or enters a building through joints, couplings, junctions, or the surfaces enclosing the building. It also refers to the uncontrolled flow of air within a building through cracks or openings.
Air Ventilation
The share of supply air that consists of outdoor air, along with any recirculated air that has been filtered or otherwise treated to maintain acceptable indoor air quality.
Air Volume
The amount of air delivered to a space through ventilation, typically specified in litres per second (L/s) or cubic metres per minute (m³/min).
Building Envelope
The physical barrier between the exterior and the conditioned environment of a building that resists the transfer of air, water, moisture, heat, cold, light, and noise.
For an air-conditioned building, the building envelope comprises the elements that separate conditioned spaces from the exterior. Crown extensions to the façade that cover plant-screen cladding are part of the building envelope. The building envelope does not include the physical barrier below ground.
Building Management System (BMS)
A computer-based control system that controls and monitors the mechanical and electrical equipment in a building, such as ventilation, lighting, power systems, fire systems, and security systems. It may also control and monitor multiple buildings.
Building Services
All the necessary services required to operate a building, such as plumbing, mechanical, electrical, and other services.
Chilled Water System
This is a system that uses water to cool the air in a building. The water is chilled to a low temperature and then circulated through pipes to cool the air.
Commissioning
A quality-oriented process for achieving, verifying, and documenting that the performance of facilities, systems, and assemblies meets defined objectives and criteria.
Condensation
The process through which a gas or vapour changes into liquid form. It also refers to the water produced during this process.
Control Systems
Localised controls that allow users to change or adjust the level of lighting and air conditioning in a space.
Cooling Coil
A coiled arrangement of tubing or pipe used to transfer heat between a cold fluid and air.
Cooling Load
The amount of cooling a building requires to meet the conditions specified by the relevant authority. The cooling load is determined by the output of the heat load calculation required by the authority.
Demand Control Ventilation (DCV)
A ventilation system that automatically reduces outdoor air intake below design rates when the actual occupancy of the spaces served by the system is lower than the design occupancy.
Demand is often assessed by measuring the amount of carbon dioxide (CO₂) in a space to reflect occupancy levels.
Dew Point
The temperature at which moisture in the air starts to condense into water. It is an important factor in determining the potential for moisture-related problems in buildings.
District Cooling System
A centralised cooling system used in large buildings or areas. It cools water at a central location and then circulates it through pipes to provide cooling to buildings.
Diffusers and Grilles
These are devices used to distribute air from the ductwork into different areas of a building.
Ductwork Leakage
The escape of air through cracks and gaps when air-conditioning ductwork is not airtight. Ductwork leakage results in increased energy consumption by supply and return air fans.
Exhaust Air
Air removed from a building space and discharged outside the building through a mechanical or natural ventilation system.
Fan Coil Unit (FCU)
This is a device used to cool or heat air in a building. It contains a fan and a coil of piping through which chilled or heated water circulates.
Global Warming Potential (GWP)
The contribution of greenhouse gases released into the atmosphere to the global warming phenomenon.
Heat Load Calculation
The process of calculating the total heat generated inside a building by various sources.
Heating, Ventilation, and Air-Conditioning (HVAC) System
Equipment, distribution systems, and terminals that provide, either individually or collectively, heating, ventilation, or air conditioning to a building or a portion of a building.
Humidity Control
This is the process of controlling the level of humidity in a building to ensure a comfortable and healthy environment for occupants.
Indoor Air Quality (IAQ)
This refers to the quality of air inside a building, including factors such as temperature, humidity, and pollutants.
Latent Heat
The heat absorbed or released when a substance undergoes a change in phase, such as changing from liquid to gas.
Make-up Air
Air deliberately brought into a building from the outdoors and supplied near an exhaust hood to replace the air and cooking effluent being exhausted.
Make-up air is generally filtered and fan-forced. It can be heated or cooled depending on the requirements of the application.
Mechanical System
Systems within a building that include components of mechanical plant or machinery. These systems include, but are not limited to, the HVAC system of a building.
Mechanical Ventilation
Ventilation provided by mechanically powered equipment, such as fans.
Minimum Efficiency Reporting Value (MERV)
A rating that indicates the filtering efficiency of an air filter evaluated using the ASHRAE 52.2 test procedure.
The performance of an air filter is determined by comparing airborne particle counts upstream and downstream of the air filter, or other air-cleaning device, under test conditions. A higher MERV rating indicates higher air filtration efficiency.
Mixed-mode Ventilation
A combination of mechanical and natural ventilation.
Monitoring Equipment
Equipment used to measure and record the status or conditions of a building, or to verify preset conditions and provide control or alarm functions when conditions vary.
Natural Ventilation
Ventilation provided by thermal, wind, or diffusion effects through windows, doors, or other openings in a building.
Relative Humidity
The amount of moisture in the air relative to the maximum amount of moisture the air can hold at a given temperature. It is expressed as a percentage.
Sensible Heat
Heat that can be felt or sensed by a person or object. It is related to changes in temperature.
Thermal Comfort
This refers to the level of comfort occupants experience in terms of temperature and humidity.
Variable Air Volume (VAV) System
A type of HVAC system that adjusts the amount of air circulated based on the cooling or heating requirements of different areas in a building. It helps save energy by avoiding the circulation of more air than necessary.
Ventilation System
A system that brings fresh air into a building and circulates it throughout the space.


